Bushfire Mesh Range

BUSHFIRE MESH RANGE

Bushfire Mesh is a versatile product that is used to defend property and homes against the 3 threats of bushfires.

Bushfire Mesh is installed to protect against embers penetrating gaps within a home or building during a bushfire.

AS3959-2018 Construction of buildings in bushfire-prone areas.

Various sections of AS3959 – 2018 requires a mesh to be used for screens or closing gaps greater than 3mm.

SSWM Bushfire Mesh Shield range has been independently verified by CSIRO and meets the physical properties of AS3959 – 2018.

Installation of Bushfire Mesh TOUGH along exterior perimeter fence.

98.5% of embers that pass bushfire mesh are no longer a threat.

INDEPENDENTLY TESTED & CERTIFIED

Bushfire Mesh TOUGH shield testing at USQ Toowomba, under bushfire conditions in a ‘mini dragon’ to evaluate its effectiveness in stopping dangerous embers

SSWM Bushfire Mesh Effectiveness Against Embers Test
Play Video about SSWM Bushfire Mesh Effectiveness Against Embers Test

Bushfire Mesh TOUGH maintains its integrity and form withstanding over 980 degrees celcius.

SSWM’s Bushfire Mesh range exceeds the requirements of AS 3959. Testing has been undertaken by independent organisations for the 3 threats of bushfires:

Ember Attack
Radiant Heat
Direct Flame

WHAT THE EXPERTS SAY ABOUT EMBER PROTECTION
“A Fine metal mesh screen is a really good choice, something like stainless is going to give you a really good design life but it is also particular strong even if the wire gauges is very fine. 2mm or smaller aperture between the strands of wire give you a fine enough screen so that embers that try to get through those if any do get through are so small that they have very little to no chance to igniting anything combustible behind it. 2mm or finer aperture stainless mesh would be thego-to.”

Justin Leonard, 31st August 2023
Source: Bushfire Resilience Inc 2023 Webinar 3

INDEPENDENT TESTING AUTHORITIES

CHOOSE FROM OUR RANGE TO MEET YOUR NEEDS

SSWM have a range of bushfire shield materials that exceed the requirements of AS 3959. We have protection that can meet your Building’s Bushfire Attack Level (BAL) to deliver the performance you require. Our range of Bushfire Mesh Shield can be used for vents & weepholes, subfloor spaces and door & window protection against embers, flame and radiant heat. To determine the most appropriate product for your application start with your building BAL rating.

Bushfire Mesh

FLEXI Shield

FLEXI, a pliable, lightweight mesh that’s easy to manipulate and can be cut with scissors. It’s often referred to as insect mesh, boasting the smallest aperture in our product range at 1.23mm.

Requiring support, FLEXI is a popular choice for retrofitting existing fiberglass insect screens, available in 15 and 30 meter rolls across four different widths, providing flexibility to meet various needs.

Typically installed for BAL Low to 12.5

915 mm Width
15 m Length

FROM
$375 + GST
MOST POPULAR

Bushfire Mesh

TOUGH Shield

Our highly popular TOUGH mesh, ideal for residential use, is easily shaped and maintains its form through memory recognition.

It can be cut with tin snips, is suitable for the widest range of applications and the most popular choice for subfloor protection.

Typically installed for BAL 12.5, 19, 29 & 40

915 mm Width
15 m Length

FROM
$855 + GST

Bushfire Mesh

EXTREME Shield

EXTREME is a heavy-duty mesh with a dual role: a strong security barrier and a resilient bushfire protective shield. Its ability to withstand extreme heat and potential fire hazards makes it an ideal choice for areas prone to intense bushfires.

Typically installed in areas with Bushfire Attack Level (BAL) 40 to Flame Zone (FZ) ratings, EXTREME showcases exceptional strength even in the most extreme environmental conditions.

Typically installed for BAL 40 & FZ

750 mm Width
2,000 mm Length

FROM
$252 + GST

Bushfire Mesh

ULTIMATE Shield

ULTIMATE, an industrial grade heavy mesh, is highly durable and renowned for its robustness. It serves as both a strong security barrier and a protective layer for bushfire defense.

It is often installed in BAL 40 to FZ areas, requiring tools like a grinder or guillotine for precise fitting. Conveniently available in 30-meter rolls with three width options, it offers flexibility to suit diverse project needs.

Typically installed for BAL 40 & FZ

915 mm Width
30 m Length

FROM
$2,880 + GST

THE DIFFERENCE BETWEEN THE FINISHES

Black Powder Coat

  • Often specified for residential use
  • Absorbs the light and allows for excellent visibility
  • Will not tea stain and requires less maintenance

Stainless Steel (Uncoated/raw)

  • Often specified for industrial applications as matches ductware
  • If being used for aesthetic purposes to minimise tea staining evaluate if the mesh should be pickled, passivated and electropolished

SHIELD YOUR HOME FROM BUSHFIRES

SSWM Bushfire Mesh is certified and part of your solution
for your bushfire protection.
Access our Bushfire Mesh Shield brochure for expert
insights into product and testing performance.

COMMON APPLICATIONS

THE 8 WAYS YOU CAN PREPARE YOUR HOME FOR BUSHFIRES

1

2

2

3

4

5

6

6

7

8

Vents & Weepholes
Window & Door Screens
Roofs
Evaporative Air Cooling Systems
Eaves & Awnings
Subfloor Spaces, Verandahs & Decks
Gutter & Valley Leaf Guard
Perimeter Fence
Shelter in Place

FLEXI - Shield

Vents & Weepholes
Window & Door Screens
Roofs
Evaporative Air Cooling Systems
Eaves & Awnings
Subfloor Spaces, Verandahs & Decks
Gutter & Valley Leaf Guard
Perimeter Fence
Shelter in Place
MOST POPULAR

TOUGH - Shield

Vents & Weepholes
Window & Door Screens
Roofs
Evaporative Air Cooling Systems
Eaves & Awnings
Subfloor Spaces, Verandahs & Decks
Gutter & Valley Leaf Guard
Perimeter Fence
Shelter in Place

EXTREME - Shield

Vents & Weepholes
Window & Door Screens
Roofs
Evaporative Air Cooling Systems
Eaves & Awnings
Subfloor Spaces, Verandahs & Decks
Gutter & Valley Leaf Guard
Perimeter Fence
Shelter in Place

ULTIMATE - Shield

Vents & Weepholes
Window & Door Screens
Roofs
Evaporative Air Cooling Systems
Eaves & Awnings
Subfloor Spaces, Verandahs & Decks
Gutter & Valley Leaf Guard
Perimeter Fence
Shelter in Place

BUSHFIRE MESH SHIELD COMPARISON & SELECTION TABLE

SSWM Bushfire Mesh range has been designed so there is a mesh that suits any application, from soft to rigid, wide to narrow and the percentage open allows for excellent visibility. The primary use of the mesh is built for bushfire protection, how and where you install your mesh will determine which mesh is appropriate.

EXCEEDS AS 3959
Parent Code
BAL LOW - FZ (typically installed)
Secondary Application

FLEXI - Shield

915 mm W
15 m L

FROM
$375 + GST
SSWOB 01230
Low, 12.5
Insect Mesh
MOST POPULAR

TOUGH - Shield

915 mm W
15 m L

FROM
$855 + GST
SSWOB 01670
SSWO 01670
12.5, 19, 29 & 40
Pet Mesh

EXTREME - Shield

750 mm W
2,000 mm L

FROM
$252 + GST
SSWOBS 01510
40, FZ
Security Mesh

ULTIMATE - Shield

915 mm W
30 m L

FROM
$2,880 + GST
SSWO 01640
40, FZ
Industrial Mesh
PRODUCT SPECIFICATION
Parent Code
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Aperture x Wire Diameter
Open Area %
Pre black powder coat finish
$
Malleable - SOFT
1.23 x 0.18 mm
76%
$$
Self Supporting - FLEXIBLE
1.67 x 0.45 mm
62%
$$$
Self Supporting - RIGID
1.51 x 0.80 mm
43%
$$$$
Self Supporting - RIGID
1.64 x 0.90 mm
42%
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

610 mm x 30 m
915 mm x 15 m
915 mm x 30 m
1220 mm x 15 m
1220 mm x 30 m
1550 mm x 15 m
1550 mm x 30 m
190 mm x 30 m
915 mm x 15 m
915 mm x 30 m
1245 mm x 15 m
1245 mm x 30 m
1550 mm x 15 m
1550 mm x 30 m
1830 mm x 30 m
750 mm x 2000 mm
750 mm x 2400 mm
900 mm x 2000 mm
900 mm x 2400 mm
1200 mm x 2000 mm
1200 mm x 2400 mm
1500 mm x 2000 mm
1500 mm x 2400 mm
915 mm x 30 m
1245 mm x 30 m
1550 mm x 30 m
EXCEEDS AS 3959
Parent Code
BAL LOW - FZ (typically installed)
Secondary Application

FLEXI - Shield

915 mm W
15 m L

FROM
$375 + GST
SSWOB 01230
Low, 12.5
Insect Mesh
MOST POPULAR

TOUGH - Shield

915 mm W
15 m L

FROM
$855 + GST
SSWOB 01670
SSWO 01670
12.5, 19, 29 & 40
Pet Mesh
PRODUCT SPECIFICATION
Parent Code
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Aperture x Wire Diameter
Open Area %
Pre black powder coat finish
$
Malleable - SOFT
1.23 x 0.18 mm
76%
$$
Self Supporting - FLEXIBLE
1.67 x 0.45 mm
62%
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

610 mm x 30 m
915 mm x 15 m
915 mm x 30 m
1220 mm x 15 m
1220 mm x 30 m
1550 mm x 15 m
1550 mm x 30 m
190 mm x 30 m
915 mm x 15 m
915 mm x 30 m
1245 mm x 15 m
1245 mm x 30 m
1550 mm x 15 m
1550 mm x 30 m
1830 mm x 30 m
EXCEEDS AS 3959
Parent Code
BAL LOW - FZ (typically installed)
Secondary Application

EXTREME - Shield

750 mm W
2,000 mm L

FROM
$252 + GST
SSWOBS 01510
40, FZ
Security Mesh

ULTIMATE - Shield

915 mm W
30 m L

FROM
$2,880 + GST
SSWO 01640
40, FZ
Industrial Mesh
PRODUCT SPECIFICATION
Parent Code
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Aperture x Wire Diameter
Open Area %
Pre black powder coat finish
$$$
Self Supporting - RIGID
1.51 x 0.80 mm
43%
$$$
Self Supporting - RIGID
1.64 x 0.90 mm
42%
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

750 mm x 2000 mm
750 mm x 2400 mm
900 mm x 2000 mm
900 mm x 2400 mm
1200 mm x 2000 mm
1200 mm x 2400 mm
1500 mm x 2000 mm
1500 mm x 2400 mm
915 mm x 30 m
1245 mm x 30 m
1550 mm x 30 m

FLEXI - Shield

915 mm W
15 m L

FROM
$375 + GST
EXCEEDS AS 3959
Parent Code
SSWOB 01230
BAL LOW - FZ (typically installed)
Low, 12.5
Secondary Application
Insect Mesh
PRODUCT SPECIFICATION
Parent Code
$
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Malleable - SOFT
Aperture x Wire Diameter
1.23 x 0.18 mm
Open Area %
Pre black powder coat finish
76 %
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

610 mm x 30 m
915 mm x 15 m
915 mm x 30 m
1220 mm x 15 m
1220 mm x 30 m
1550 mm x 15 m
1550 mm x 30 m
MOST POPULAR

TOUGH - Shield

915 mm W
15 m L

FROM
$855 + GST
EXCEEDS AS 3959
Parent Code
SSWOB 01670
SSWO 01670
BAL LOW - FZ (typically installed)
12.5, 19, 29 & 40
Secondary Application
Pet Mesh
PRODUCT SPECIFICATION
Parent Code
$$
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Self Supporting - FLEXIBLE
Aperture x Wire Diameter
1.67 x 0.45 mm
Open Area %
Pre black powder coat finish
62 %
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

190 mm x 30 m
915 mm x 15 m
915 mm x 30 m
1245 mm x 15 m
1245 mm x 30 m
1550 mm x 15 m
1550 mm x 30 m
1830 mm x 30 m

EXTREME - Shield

750 mm W
2,000 mm L

FROM
$252 + GST
EXCEEDS AS 3959
Parent Code
SSWOBS 01510
BAL LOW - FZ (typically installed)
40, FZ
Secondary Application
Security Mesh
PRODUCT SPECIFICATION
Parent Code
$$$
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Self Supporting - RIGID
Aperture x Wire Diameter
1.51 x 0.80 mm
Open Area %
Pre black powder coat finish
43 %
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

750 mm x 2000 mm
750 mm x 2400 mm
900 mm x 2000 mm
900 mm x 2400 mm
1200 mm x 2000 mm
1200 mm x 2400 mm
1500 mm x 2000 mm
1500 mm x 2400 mm

ULTIMATE - Shield

915 mm W
30 m L

FROM
$2,880 + GST
EXCEEDS AS 3959
Parent Code
SSWO 01640
BAL LOW - FZ (typically installed)
40, FZ
Secondary Application
Industrial Mesh
PRODUCT SPECIFICATION
Parent Code
$$$
Roll or Sheet / Cutting
Finish
Formabilty (handling)
Self Supporting - RIGID
Aperture x Wire Diameter
1.64 x 0.90 mm
Open Area %
Pre black powder coat finish
42%
QUALITY ASSURED
Compliant
Tested
Certified
AS 3959-2018 Amdt 1
Compliant
CSIRO FCO-3313 Rev B
Independently verified
AS/NZS 1530.3:1999
Ignitability
AS 2331 1.3.1 2001
Neutral Salt Spray Test
AS 5041 2003
Knife Shear Test
SHIELD PROTECTION
USQ Project 1007952
Ember Attack
AS 1530.8.1
Radiant Heat
ASTM E2886
Direct Flame
DIMENSIONS     W x L

Australian Standards:
SSWM bushfire mesh can be used to meet the requirements of AS3959-2018 for BAL 12.5 -FZ, where mesh is referenced and if the prescribed construction requirements are met.

Independently Verified:
SSWM Bushfire Shield Mesh range has been independently verified by CSIRO and met the physical properties of AS3959-2018.

915 mm x 30 m
1245 mm x 30 m
1550 mm x 30 m

Bushfire Attack Level (BAL)
Bushfire Mesh Shield can be used to meet the requirements of AS3959 for BAL low to FZ where mesh is referenced and if the prescribed construction requirements are met.

Quick Quote

Same day despatch when your order is received by 9am.

INSTALLATION IS EASY

Before commencing your installation you should consult a Fire Protection Australia (FPA) & Bushfire Planning and Design (BPAD) Accredited Practitioner and contact your local council and fire authority to ensure you are meeting all the building and AS3959-2018 requirements.

REQUEST A QUOTE

Complete the form below and we will get back to you as soon as possible.

Quote information

Your quote is currently empty.

Return To Shop

Request a Quote

Your Details

 

Product

Intended Use

Delivery Details for Quoting

General Enquiry