Residential
Bushfire Protection Mesh
BUSHFIRE MESH RANGE
Our residential Bushfire Mesh Shield range is a versatile product, that can be fully customised to best meet the requirements of your unique applications. Our product can be installed over your vents, under your decks and between your wall and roof gaps which saves you money. With our user-friendly residential DIY guide, you can identify, select, and install your Bushfire Mesh efficiently and easily.
Various sections of AS3959-2018 Construction of buildings in bushfire-prone areas, requires a mesh to be used for screens or closing gaps greater than 3mm.
SSWM Bushfire Mesh Ember Stop range has been independently verified by CSIRO and meets the physical properties of AS3959- 2018:
- Mesh with max aperture of 2mm
- Corrosion resistant steel
- Non combustible
STAINLESS STEEL SHIELD BUSHFIRE MESH
Reflect, absorb and diffuse with Bushfire Mesh Shield – protection against ember attack, radiant heat and direct flame.
SSWM Bushfire Mesh Range is designed to suit any application, from soft to rigid, wide to narrow.
Same Day Despatch
Freight friendly rolls quickly despatched to rural areas
Quality Assured & Tested
98.5% of embers that pass Bushfire Mesh are no longer a threat
Easy Installation
No specialty skills or tools are required
HOW CAN YOU PREPARE YOUR HOME
TO BE MORE RESILENT TO BUSHFIRES IN AUSTRALIA?
Preparing your home for bushfires is an important step in ensuring the safety of you and your family. By using Bushfire Mesh Shield, you can take proactive steps to protect your home and make it more resilient to bushfires. The mesh is easy to install and can be used on a variety of different building types, making it part of your solution for your bushfire protection.
You can be confident that Bushfire Mesh Shield will protect your home as it exceeds the Australian Standards and has been verified by CSIRO. Bushfire Mesh Shield is non corrosive, non combustible and has an aperture less than 2mm.
THE 8 WAYS YOU CAN PREPARE YOUR HOME FOR BUSHFIRES
Vents & Weepholes
Openings larger than 2mm should be sealed with Bushfire Mesh to catch, hold and release embers from entering building space.
Screens for Windows & Doors
External windows and doors should be fitted with Bushfire Mesh screens to reflect and absorb radiant heat. This will stop glass from cracking and falling out and allowing embers into the building.
Roofs & Walls
Bushfire Mesh should be used to seal off ventilation openings greater than 2mm to stop dangerous embers reaching the roof space.
Roof Penetration (Evaporative air cooling system)
Should be fitted with Bushfire Mesh covers with max. aperture of 2mm to stop embers from entering the building.
Eaves & Awnings
Should be covered to avoid birds from nesting and their nesting becoming a fuel source for when embers ignite.
Subfloor spaces Verandahs & Decks
Install screens to prevent combustible material building up under the decks and for embers to enter the area. Screens can be dug into the ground and will not corrode as it is 316 stainless steel.
Gutter & Valley Leaf Guard
Install Bushfire Mesh guards to stop leaves and debris collecting in gutters and becoming a fuel source for embers.
Perimeter Fence
Install Bushfire Mesh around boundaries. Bushfire mesh will act as an ember shield and flame arrestor and deflect flames. This then becomes your first line of defense during a bushfire.
INSTALLATION IS EASY
- No specialised skills or tools are required
- Can be retrofitted to existing properties
- Installation is simple and quick
- Mesh comes in different widths & lengths and allows customisation to protect your space
Before commencing your installation you should consult a Fire Protection Australia (FPA) & Bushfire Planning and Design (BPAD) Accredited Practitioner and contact your local council and fire authority to ensure you are meeting all the building and AS3959-2018 requirements.
PROJECTS ACROSS AUSTRALIA
WHAT OUR CUSTOMERS SAY
WE HAVE A VERY DIVERSE CUSTOMER BASE
From residential, community, industrial / agriculture & bushfire practitioners. We also have a strong presence in various industry sectors from construction to defence, energy and government.
COMPLIMENTARY PRODUCT CONSULTATION
Speak with a product expert regarding your project
SAME DAY DESPATCH
when your order is received
by 9am for Australia wide delivery
SAME DAY DESPATCH
when your order is received
by 9am for Australia wide delivery
| Bushfire Attack Level (BAL) | Description | Section from AS 3959: 2018 Construction section |
| Low | Insufficient risk to warrant specific construction requirements | Section 4 |
| 12.5 | Ember attack | Section 3 & 5 |
| 19 | Increasing levels of ember attack and burning debris ignited by windborne embers together with increasing heat flux | Section 3 & 6 |
| 29 | Increasing levels of ember attack and burning debris ignited by windborne embers together with increasing heat flux | Section 3 & 7 |
| 40 | Increasing levels of ember attack and burning debris ignited by windborne embers together with increasing heat flux with the increased likelihood of direct contact with flame | Section 3 & 8 |
| FZ | Direct exposure to flames from fire front in addition to heat flux and ember attack | Section 3 & 9 |
BAL Rating | Low | 12.5 | 19 | 29 | 40 | Flame Zone (FZ) |
|---|---|---|---|---|---|---|
SSWM Suitable Product | Flexi | Flexi | Tough | Tough | Extreme & Ultimate | Extreme & Ultimate |
- Flexi – aperture of 1.23mm and wire diameter of 0.18mm
- Tough – aperture of 1.67mm and wire diameter of 0.45mm
- Extreme – aperture of 1.51mm and wire diameter of 0.8mm
- Ultimate – aperture of 1.64mm and wire diameter of 0.9mm
- Fire danger index of the region
- The vegetation classification
- The distance from the building to the fuel load
- The slope of the area
- Ember Attack – Small burning combustible material that are transported by the wind
- Radiant Heat – The heat generated from a fire that is transferred using radiation waves
- Direct Flame – The heat generated through conduction of a flame to an object
- SSWM Product Selection Guide & Planning Guide are great resources and tools to select the most appropriate mesh for your application. A customer will need to consult and confirm with their local fire authority or Bushfire Planning and Design (BPAD) Accredited Practitioner and contact your local council to ensure that you are meeting all the building and AS3959-2018 requirements. Remember Bushfire Mesh is a part of the total solution.
- It is manufactured to ISO 9000 Quality Standards
- It is strong and can keep animals and insects out of protected spaces
- Available in black powder coated finish and blends into the environment
- Provides a privacy feature when installed
- Supplied with additional wires, top and bottom to make securing easy
- Has been independently tested and passas all the Australian Standards (AS 3959)
- Meets the Respective Australian Building Codes
- Meets the Highest Bushfire Attack Level BAL-FZ requirements
- Class A rated product per UL 723 / ASTM E84
- When there is no fire situation: The Bushfire Mesh (woven mesh) allows airflow and will allow areas that get wet to dry out
- When there is a Fire situation: The Bushfire Mesh (woven mesh) allows airflow and the mesh acts as a filter that “knocks out” embers as they are carried by the winds
- Solid metal barriers deflect the wind up and over the fence leaving the ember in the wind allowing the ember to enter the defendable space
- Solid fences require large footings as they are subject to the full force of the wind
- Woven Mesh is strong and it keeps its shape
- Stainless steel has a high melting point and the research states that the protection should be able to withstand 900+ degrees C where as aluminium Melts at 700 Degrees C
- Stainless steel is non corrosive and low maintenance where as galvanised steel loses its non corrosive protection over time
- Stainless steel is non combustible and will not increase your building fire load
- Stainless steel can reflect Radiant heat resulting in a lower temperature on the non fire side. This lower temperature will reduce the likelihood of fire continuing beyond the barrier
- Non combustible
- Non-corrosive
- Opening size less than 2mm
Our showroom and dispatch operate from 8:30am to 3:30pm, Monday to Friday. We are closed on weekends and public holidays.
Yes, we welcome visitors! Please prearrange your visit so we can assist you without interruption and ensure the right team member is available.
We accept payment via EWAY or direct deposit (EFT). For security reasons, we do not accept credit card details over the phone.
Absolutely. You’re welcome to arrange your own freight provider. Please notify us in advance so we can coordinate pickup and documentation.
Orders received before 9:00am are dispatched same day. Orders received after 9:00am will be dispatched the next business day.
Yes. Once your order is dispatched, we’ll send you a tracking link or consignment number via email.
We have a technical datasheet for each product:
These include a to scale image, specifications, dimensions and weights. These are found on the website product page under the “PRODUCT SPECIFICATION” tab. We also include a link to the relevant datasheet in all quotes, proformas and invoices.
We stock pre-cut rolls in 15 metre and 30 metre lengths.
Yes. We offer volume-based pricing and trade discounts for approved resellers and commercial customers. Contact us for a quote.
Yes. Pickup is available from our Tullamarine, VIC or Sunnybank Hills, QLD warehouse. Please confirm your pickup time so we can have your order ready.
Bushfire Mesh is supplied as a DIY or contractor-installed product. We do not offer installation services but can recommend experienced installers in your area and you can refer to our SSWM Bushfire Mesh DIY Guide.